We repair Arctic Air refrigerators, freezers and prep tables for Denver Metro restaurants, bars, cafes and stores. Our EPA-608 certified technicians handle reach-ins, undercounters, chef bases and bar units.
Wilson & Myers handles Arctic Air refrigerator repair for Denver Metro restaurants, bars, cafes and stores. Our insured technicians cover every Arctic Air commercial refrigerator family within our commercial refrigerator repair work. Past the factory term, the repair is ours. We find the fault and back the labor with our 100-day warranty.
Every current Arctic Air unit is self-contained, plugs into 115 V and runs R290 on a capillary tube. Arctic Air lists no walk-in or ice machine today. Arctic Air freezer repair runs through our commercial freezer repair work, since the freezers share manuals and controls.
On an Arctic Air AR23 reach-in refrigerator, the serial sticker sits on the left inner wall near the top. An Arctic Air AUC27R uses the same spot. Chef bases carry it outside on the left side and on the back.
A plate may add a letter suffix, such as AR23EZ. Arctic Air refrigeration sits beside the other commercial refrigeration brands we service.
| Family | Models | Code table in the manual |
|---|---|---|
| Solid reach-ins | AR23, AR49; AF23, AF49 freezers | Yes |
| Glass reach-ins | AGR23, AGR49; AGDF23, AGDF49 freezers | Yes |
| Merchandisers | ARGDM23, ARGDM49; AFGDM23, AFGDM49 | No |
| Economy | AWR25; AWF25 freezer | No |
| Undercounters | AUC27R to AUC60R; AUC27F to AUC60F | Yes |
| Prep tables | APP pizza; AST and AMT sandwich | Yes |
| Countertop rails | ACP40 to ACP63 | No |
| Chef bases | ARCB36 to ARCB72 | No |
| Bar units | ABB, ADD, AUB, AGF | Shorter list on ADD keg coolers; none on the others |
These codes are printed in the AR, AF, AGR, AGDF, APP, AST, AMT and AUC manuals. Keg coolers print a shorter list without P3 or CSd. Other families print no code meanings.
Press Up or Down to see the last alarm. To clear it, hold SET until rst appears, then press SET again. Up and Down held together for 3 seconds lock (POF) or unlock (Pon) the keys.
A probe code that comes back after a reset, or a CA or CSd, means a call to us.
| Code | Cause as printed | What the outputs do |
|---|---|---|
| P1 | Room probe failure | Compressor runs on its Con and COF settings |
| P2 | Evaporator probe failure | Defrost ends on a timer |
| P3 | Condenser probe failure | Outputs unchanged |
| HA | Maximum temperature alarm | Outputs unchanged |
| LA | Minimum temperature alarm | Outputs unchanged |
| dA | Door open | Compressor and fans restart |
| EA | External alarm | Outputs unchanged |
| CA | Serious external alarm | All outputs off |
| CSd | Condenser alarm | All outputs off |
All four of these are normal. A defrost that never ends, or a coil frozen between cycles, comes to us.
Most units stop every 6 hours and show the defrost symbol. Defrost ends when the coil reaches 45°F on freezers such as the Arctic Air AF23, 41°F on refrigerators, or after 20 minutes.
The anti-short-cycle delay, not a fault.
The fan delay after a defrost.
No defrost system. Shut the rail off to defrost it.
Cold air leaves at the top rear and must reach the bottom. Bags pushed against the back block it. That can freeze the coil, warm the cabinet or overflow the drain pan. An Arctic Air prep table must run with its pans and covers in place, and the pans are emptied overnight.
An Arctic Air refrigerator not cooling after these checks needs a technician’s diagnosis. That part is ours. Our preventive maintenance visits keep the coil cleaning on schedule.
Switch the unit off and unplug it before any step below.
These install facts from the manuals can cost coverage before any part fails. If an install broke one, the Warranty Center may refuse the claim. The repair is then ours.
Every current unit runs R290. It is propane, and it is flammable. For the refrigerant circuit, the manuals print precautions including no flame leak detector, like-for-like components, and refrigerant recovered before brazing. Never chip ice off the coil with a tool.
Our EPA-608 certified technicians follow those precautions on every sealed-system job. That covers leak diagnosis and compressor work. Controllers, probes, fans and defrost faults are ours too, as across our commercial appliance repair.
Units bought on or after July 15, 2026 carry three years of parts and labor, capped at 30 months from shipment. Three more years then cover the compressor part only. Gaskets and bulbs get 90 days, hinges one year.
ACP rails get one year of parts and labor and no compressor extension. The AWR25 and AWF25 get one year of parts and labor. Food trucks and outdoor installs get one year in all. Residential use is not covered.
Most units bought before July 15, 2026 were sold under two years of parts and labor and five on the compressor. ACP rails and the economy pair had one year of parts and labor. Proof of purchase settles which term applies. Every warranty call must be pre-approved by the Arctic Air Warranty Center, which arranges the service provider.
The warranty never pays for spoiled product, coil neglect, extension cords or gaskets after 90 days. The repairs behind those failures are ours. So is every unit past its term.
We source parts through national supplier networks and manufacturer contracts. Arctic Air parts are ordered once the diagnosis names the component. Arctic Air freezer parts, such as the AWF25’s defrost heater, follow the same rule.
With the unit unplugged, clean the coil, reseat the drain tube and tighten the hinges. Then check airflow with it running. If the display shows CA or CSd, a probe code returns, or the coil ices between defrosts, the job is ours. In my experience, an owner who has done those checks hands us a clearer starting point.
Book an Arctic Air repair with the model from the sticker and the display reading.
Why is my Arctic Air commercial refrigerator not cooling?
Start with the condenser coil and airflow. Packed shelves can freeze the evaporator coil. An Arctic Air undercounter refrigerator gets the same checks. A coil that stays iced between defrosts needs a technician.
What does HA mean on an Arctic Air display?
HA is the maximum temperature alarm. That meaning is printed in the reach-in, glass reach-in, prep table, undercounter and keg cooler manuals. Its outputs stay unchanged. Check airflow and the condenser coil, then call us if it returns.
Why does my Arctic Air shut off every few hours?
On most Arctic Air units, that is the 6-hour automatic defrost. The display shows the defrost symbol while it runs. ACP countertop rails have no defrost system, so it does not apply to them.
How often should I clean an Arctic Air condenser coil?
At least every 90 days, every 60 on keg coolers and every 30 in a dusty or greasy kitchen. Unplug the unit first. Neglect voids the compressor coverage.
Does the Arctic Air warranty cover spoiled food?
No. The warranty document excludes food or product spoilage and other consequential loss. In-term repairs also need pre-approval from the Arctic Air Warranty Center before work starts.
Tell us the model from the sticker on the unit and what the display shows. Our EPA-608 certified technicians repair Arctic Air refrigerators, freezers and prep tables across Denver Metro.
Repair and maintenance notes from our Denver Metro technicians on commercial refrigerators, freezers and prep tables.

Most cases of a Maytag dryer not heating split at the model prefix on the door: MGDC is gas, MEDC is electric, and the path diverges from there. On a Centennia…

You open the freezer Friday night and the GE side-by-side ice bin is empty, but the food is cold and the water dispenser works fine. Most GE refrigerator ice m…

A Samsung washer not spinning leaves clothes wet in the drum and the dryer waiting. Samsung's four platforms handle this differently: WF front-load, WA top-loa…

You opened the KitchenAid freezer this morning and the bin was empty. In my experience, the arm is the first thing worth checking: the fix costs nothing and ta…

A Frigidaire oven not heating can come down to a setting rather than a part. Before you book a repair, two checks cost nothing and take under a minute: the clo…

A Whirlpool dryer that tumbles but never heats traces to one of five faults, and three of them cost nothing to check. Here is the order to work through them, p…

F8 E4 means water reached the drip tray, not a fill fault. Here is the two-step reset and why it can fire on a brand-new install with a dry tray…

A Bosch dishwasher E22 error means one thing: the filter is blocked, and there is probably water sitting in the bottom of the tub…

A Frigidaire refrigerator not cooling is not always a broken refrigerator. The display on the door settles that question in about ten seconds…

You walked into the laundry room and the display is flashing D80. The drum is still turning. You do not know whether to stop the cycle or let it finish. D80 is…

A GE refrigerator not cooling usually falls into one of two failure paths. The question is simple: is the freezer still cold? If yes, the sealed system is inta…

You pull open the freezer on a July evening and find an empty bin. A Frigidaire ice maker not working in peak summer is one of the most frequent calls our Denv…
We travel to restaurants, bars, cafes and stores across Denver Metro for Arctic Air refrigerator and freezer repair. Contact us to confirm coverage for your location.
We repair every current Arctic Air family. That means reach-ins, glass doors, merchandisers, economy units, undercounters, prep tables, countertop rails, chef bases and bar units. Tell us the model from the sticker on the unit and what the display shows. We source parts through national supplier networks and manufacturer contracts, and every paid repair carries our 100-day labor warranty.
Wilson & Myers is a verified member of the Denver Metro Chamber of Commerce.
The use of any materials from this resource is possible only after the written consent of the copyright owner.