Your KitchenAid Ice Maker Stopped Making Ice. Start Here.
You opened the KitchenAid freezer this morning and the bin was empty. In my experience, the arm is the first thing worth checking: the fix costs nothing and ta…
Call us & text us 24/7
Four current Whirlpool vented dryer manuals were read end to end for this page. None of them prints an error code table. Whirlpool dryer error codes live on its support site instead, where one number can mean two things. Which machine you own decides which meaning applies.
An F code means Whirlpool has already decided: the control found a problem needing service.
Whirlpool states that the dryer keeps running with AF and F4E3 present. So a Whirlpool dryer not drying clothes while the cycle still finishes is airflow, not a shutdown. A Whirlpool dryer control board fault reads as F6E1.
Fourteen more residential codes have a Whirlpool page with no stated meaning, only a power cycle procedure. Any list that gives those a meaning is sourcing it elsewhere.
| Code | What Whirlpool says it means | Subsystem |
|---|---|---|
| AF or Check Vent | Lint screen or vent clogged, crushed or kinked | Airflow |
| F4 E3 | Restricted air flow, the same wording as AF | Airflow |
| F4 E1 | The heater or the heater relays | Heat |
| F4 E4 and L2 | Low or no line voltage | House power |
| F2 E1 | A stuck key on the keypad, which Whirlpool titles Keypad | Control and UI |
| PF | A power failure interrupted the cycle | Power |
| ERR | The door is not closed and latched | Door |
| Loc | The Control Lock is enabled | Controls |
| F3 E2 and F3 E5 | Five loads dried with no sensor data | Sensor bars |
| F7 E1 | Motor, control or wiring | Motor |
| F6 E1 | Control board, touchpad or wiring | Control board |
| F1 and F2 codes | Control unit or user interface | Controls |
F4E3 on a standalone Whirlpool dryer is restricted air flow. On a Laundry Tower it points at the main heater. F3E2 is a moisture sensor on one and a pressure sensor switch on the other.
Merging those two tables sends a Laundry Tower owner to a vent cleaner for a heater fault. Laundry Tower is Whirlpool’s name, and WashTower is LG’s.
Compact heat pump machines use letters rather than F numbers.
| Code | Potential cause on a Laundry Tower | On a standalone dryer |
|---|---|---|
| F4 E3 | Main heater | Restricted air flow |
| F3 E2 | Pressure sensor switch | Moisture sensor |
| F3 E1 | Steam temperature sensor | Exhaust thermistor |
| F1 E1 | ACU, a control fault | No meaning published |
| F0 E3 | Over load detection | Not a standalone code |
| F5 E1 | Door switch | Not a standalone code |
| F7 E2 | MCU failure | Not a standalone code |
The current vented range is three platforms in two fuels. A Whirlpool electric dryer carries a WED number and a Whirlpool gas dryer a WGD, with the same four digits. 4307 is the 7.0 cubic foot machine, 5720 adds connectivity, 6720 steam.
The ventless side is where mistakes happen. WCD3090JW is a condensing dryer. Its near twin WHD3090GW is a heat pump, same 4.3 cubic feet, one letter apart.
A Whirlpool stackable washer and dryer built as one cabinet is a Laundry Tower. Older machines wear a series badge: a Whirlpool Cabrio dryer, a Whirlpool Duet dryer, a Whirlpool Estate dryer. The plate inside the door decides which table applies, and a Whirlpool Cabrio dryer parts order starts there.
| Platform | Heat source | Moisture leaves by |
|---|---|---|
| Vented electric, the WED numbers | 5400 W heater element | 4 inch duct outdoors |
| Vented gas, the WGD numbers | Burner, gas valve, ignitor | 4 inch duct outdoors |
| Full size heat pump, WHD862CHC and WHD560CHW | Refrigeration circuit plus a heater element | Condensate pumped to a drain |
| Compact condensing, WCD3090JW | Heat with a condensing coil | Condensate |
| Compact heat pump, WHD3090GW | Refrigeration circuit | Water tank or drain hose |
An electric machine needs a 30 amp circuit fused on both sides of the line. One circuit turns the drum and the other runs the element, in Whirlpool’s own words. Trip one and the drum tumbles while nothing gets warm.
So a Whirlpool electric dryer not heating is a panel check before a parts call. The same holds for a Whirlpool front load dryer not heating. A Whirlpool dryer not getting hot splits by fuel first, and a Whirlpool gas dryer not heating has a free check. The shutoff valve is open only when the handle is parallel to the pipe.
Past those it is a meter job. An ignitor that glows without a flame points at the gas valve coils. One that never glows points at the ignitor or the thermal cut-off. A burner that lights and drops out points at the radiant sensor.
A Whirlpool dryer thermal fuse that opens has a reason behind it, usually airflow in our own work. Whirlpool does not publish that link, so it is our view.
A dryer that heats but takes long dry times has a vent or airflow problem, in Whirlpool’s words. So no heat is a component fault, and heat with long cycles is airflow.
The opposite failure looks identical when the door opens. With a moisture sensor fault the dryer heats and stops early, leaving damp clothes. Whirlpool sets F3E2 when five consecutive loads finish without sensor data. Its name for the bars is Sensor, Electrode.
Before that becomes a parts call the machine has to be level, with a load big enough to touch the sensor bars. WED4307SW senses temperature rather than moisture, so the sensor bar story does not fit it.
EcoBoost is on, and Whirlpool puts roughly forty minutes on the cycle.
Overloading, against Whirlpool’s one half to three quarters.
Whirlpool publishes one maximum duct length, the same for gas and electric. Elbows cost more than feet: each 90 degree turn takes 10 ft off the allowance, each 45 takes 6.
Side and bottom exhausts spend a turn inside the dryer, so add one before reading the chart. Only 4 inch heavy metal duct is allowed, plastic and foil are refused, and flexible metal is capped at 7 3/4 ft.
Whirlpool disagrees with itself on cleaning intervals. The manual says at least every two years, the support site one to two, and the engineering guide an annual inspection.
Its own fix list for F4E3 ends by telling the owner to call a venting specialist. The manual adds that service calls caused by improper venting are not covered, and the customer pays.
So the diagnosis is ours and the duct is a different job. A dryer taking too long, not drying, or running hot routes to our dryer vent cleaning page. No Whirlpool document says a restricted vent shuts a dryer down. Three signs point at the duct.
| 90 degree turns or elbows | Maximum vent run |
|---|---|
| 0 | 64 ft |
| 1 | 54 ft |
| 2 | 44 ft |
| 3 | 35 ft |
| 4 | 27 ft |
A thump in the first minutes after disuse is a flat spot on the drum support rollers, and it fades. A thump that does not fade is a Whirlpool dryer drum roller. On a heat pump a compressor hum is normal.
A Whirlpool dryer making noise when spinning is a short list. A Whirlpool dryer squeaking under load is the belt and pulleys, from lint or age. The lint version needs the back panel off, which is a service call. A rattle is usually a coin against the blower wheel, inside the Whirlpool dryer lint trap housing.
A Whirlpool dryer not spinning but heating is a shorter list: the belt, the pulley or a seized roller. Whirlpool sells the belt, the Whirlpool dryer idler pulley and the rollers as one maintenance kit, so a Whirlpool dryer belt replacement rarely travels alone. On designs with a broken belt switch a snapped belt leaves the machine silent instead of humming. F7E1 is Whirlpool’s own label for a Whirlpool dryer motor fault.
A Whirlpool dryer not starting has Whirlpool’s own order of checks behind it. When a Whirlpool front load dryer won’t start but has power, both latches are the first suspect. Behind a real no start sits a Whirlpool dryer door switch, the thermal fuse, or the control.
The clock starts at the date of delivery, not the date of purchase. For that year Whirlpool pays for factory specified parts and the labor to fit them, and the Whirlpool dryer warranty has no parts only tier.
The years two to five section lists two categories, and both are refrigerators. No dryer motor, drum or heater appears on it. The word dryer there means a refrigeration filter drier, which is where a ten year motor warranty gets invented. There is none.
One clause cuts both ways and has to be read whole. A repair from outside Whirlpool’s own service network does not void the warranty, and Whirlpool will not pay for damage caused by one.
We source parts through national supplier networks and manufacturer contracts, and timing depends on whether the supplier has the part.
Whirlpool’s gas manual carries a rule the Front Range cannot opt out of. Above 2,000 ft the burner rating needs a 4 percent reduction for each 1,000 ft. Denver sits near 5,280 ft, so every gas Whirlpool dryer here falls inside it.
That is an installation and safety matter rather than a repair one. Whirlpool never says what an unadjusted burner does in service, so neither will we. Gas supply, connectors, propane conversion and burner input are gas work, and our dryer hook up page is where that belongs.
A finished basement laundry room reaches daylight through a long run with several turns. Count the elbows before you count anything else.
Whirlpool wants 12 inches of clearance, and it names snow as an obstruction.
Below 45 degrees the cycles will not run properly, and nothing is broken.
A Whirlpool dryer not working often gets settled in ten minutes. None of the checks below needs a tool, and Whirlpool dryer troubleshooting is mostly doing them in order.
What is ours starts where Whirlpool’s own escalation starts: long dry times that survive a cleaning, no heat, codes that return, unusual noises. Anything needing a meter is ours, and so is any gas work.
In my experience the caller has already told us which it is. The two sentences we hear most are my Whirlpool dryer is not heating and my Whirlpool dryer won’t start.
Wilson & Myers runs a Whirlpool dryer repair service across Denver Metro Area with insured technicians. A search for Whirlpool dryer repair near me returns a list, and the question is whether they ask which platform you own. Whirlpool dryer service starts with your model number. The washer it pairs with sits under Whirlpool laundry appliance repair.
A Whirlpool dryer not heating up splits by fuel, not by cabinet. Electric means both breakers, gas means the shutoff handle. Past those it is the heater element, a thermal fuse, a thermostat or the gas train.
A Whirlpool Cabrio dryer not heating and a Whirlpool Duet dryer not heating run the same order. For step-by-step diagnosis by fuel type and symptom, see our Whirlpool dryer not heating guide.
Whirlpool’s own procedure is the breaker, not a button. Turn the circuit off for five minutes, turn it back on, then run a timed dry cycle.
A code that returns was never a glitch. Loc on the display is the Control Lock, and it clears from the panel.
A short cycle ending in damp clothes is usually the moisture sensor rather than the heat. Whirlpool sets F3E2 after five consecutive loads finish with no sensor data.
Small loads, an unlevel machine and softener film all do that. PF means something else: a power failure interrupted the cycle.
On the compact heat pump machines, F01 through F04 carry no published meaning at all. Whirlpool gives only the clearing step: hold Power for three seconds.
The numbered F codes older lists show for residential dryers now return nothing on Whirlpool’s site.
One year from the date of delivery, parts and labor. Nothing extends past that for a dryer, because the two to five year section covers refrigerators only. A service call caused by improper venting is excluded even inside that year.
Judge it on how repairable it is. A repair parts list is published per model with full part numbers, so a component is identified before ordering. The moisture sensor carries one part number across the gas, electric and heat pump platforms.
Tell us whether yours is gas or electric, and vented or ventless, when you book. Those two answers change the whole diagnosis.
Repair guides, maintenance tips and troubleshooting walkthroughs written by our insured technicians.

You opened the KitchenAid freezer this morning and the bin was empty. In my experience, the arm is the first thing worth checking: the fix costs nothing and ta…

A Frigidaire oven not heating can come down to a setting rather than a part. Before you book a repair, two checks cost nothing and take under a minute: the clo…

A Whirlpool dryer that tumbles but never heats traces to one of five faults, and three of them cost nothing to check. Here is the order to work through them, p…

F8 E4 means water reached the drip tray, not a fill fault. Here is the two-step reset and why it can fire on a brand-new install with a dry tray…

A Bosch dishwasher E22 error means one thing: the filter is blocked, and there is probably water sitting in the bottom of the tub…

A Frigidaire refrigerator not cooling is not always a broken refrigerator. The display on the door settles that question in about ten seconds…

You walked into the laundry room and the display is flashing D80. The drum is still turning. You do not know whether to stop the cycle or let it finish. D80 is…

A GE refrigerator not cooling usually falls into one of two failure paths. The question is simple: is the freezer still cold? If yes, the sealed system is inta…

You pull open the freezer on a July evening and find an empty bin. A Frigidaire ice maker not working in peak summer is one of the most frequent calls our Denv…

The LG washer UE code means the machine detected an unbalanced load during the spin cycle and stopped to protect the drum and bearings. UE is protection not br…

E24 on a Bosch dishwasher means the drain cycle did not complete. A clogged filter basket is the cause in most cases. If the filter is clear, the drain pump or…

When the LG washer LE code flashes mid-cycle, the drum stops, and your laundry sits locked inside. Most people's first thought is a broken motor. It usually is…
Wilson & Myers dispatches insured technicians to homes running Whirlpool appliances throughout the Denver Metro Area.
Wilson & Myers is a verified member of the Denver Metro Chamber of Commerce.
The use of any materials from this resource is possible only after the written consent of the copyright owner.