Frigidaire Ice Maker Not Working? 7 Causes and How to Fix Each
You pull open the freezer on a July evening and find an empty bin. A Frigidaire ice maker not working in peak summer is one of the most frequent calls our Denv…
Services
Blog
Services
Blog
Call us & text us 24/7
Start with the symptom people misread. On a Bosch gas cooktop the igniters all fire together, so every burner clicks when you light one. Wilson & Myers repairs Bosch gas and electric cooktops across the Denver Metro Area, and our technicians are insured.
Hear every burner clicking while you light one and the obvious conclusion is that the whole cooktop has failed. It has not. Bosch builds the ignition that way and prints a caution saying so.
There is no pilot light on these cooktops. Each burner carries its own igniter, and a flame blown out mid-cook reignites by itself. Bosch’s installation checkout for its gas ranges gives four seconds as the time a burner should take to light.
So the clicking on its own tells you almost nothing. What it does tell you is that the spark module is alive, which moves the question down to the burner itself.
This is the one almost nobody guesses, and Bosch publishes it. Its gas cooktop and rangetop list runs to exactly two entries, and the second says ignition can stop because the electronics are hot.
There is an electronics fault or error. Disconnect the appliance, wait a couple of seconds, then reconnect
The electronics have overheated. Turn all burners off, or use the minimum power level until the system has cooled
Two entries is the whole published gas list. Set that against Bosch’s own gas cooktop troubleshooting page, which says no clicking at all may mean a faulty igniter. The two branches then separate cleanly.
Clicking with no flame is a burner problem. No clicking at all is the ignition hardware, unless the display shows F2, F4 or F5, and then it is heat.
Nothing needs replacing in that second case. Turn the burners off or drop to the minimum power level, let the electronics cool, and the ignition comes back.
Bosch gas cooktops in this line are sealed burner units, and its own propane kit says so in as many words. The burner is a stack: a cap on top, a burner base under it, the igniter alongside.
Bosch names the causes it expects on that stack, and every one of them is free to rule out before anybody is dispatched.
One more startup quirk worth knowing before you call it a fault. After a power cut, or at first power up, the igniters may spark once or twice with every knob off.
Under the burners sit the parts a homeowner cannot reach. Bosch names the gas valve, the pressure regulator and the ignitor and spark module. A faulty regulator is its named cause of a flame that will not come up.
Propane is the job that surprises people. A Bosch cooktop leaves the factory set for natural gas, and Bosch requires a qualified technician or installer for the conversion.
It is not an orifice swap. Bosch’s cooktop kit reaches inside the valves themselves, which is why the instructions gate the work to a technician.
The kit is also model-specific. Bosch says its cooktop kit cannot be used to convert other Bosch sealed burner cooktops, its ranges, or any other brand.
A propane install needs two regulators as well. Bosch’s cooktop installation manual requires a high pressure regulator on the tank itself, in addition to the one shipped with the cooktop.
Altitude changes the gas side of all of this, and Bosch publishes a threshold in its installation documents. That question belongs to the whole appliance, so it lives on our Bosch range repair page.
Bosch publishes a long list for electric cooktops and a short one for ovens. The first entry worth knowing is U400, which reports that the supply voltage sits outside the normal operating range.
Bosch’s first instruction is to contact your electrical utility provider. No part on the cooktop fixes that one, because the fault is in the house supply.
Then the hardware. Bosch’s spec sheet for the 30 inch NET8068UC gives a wattage and a size for every zone. One of them is not like the others.
| Zone | Rating | Element size |
|---|---|---|
| Front left | 1,800 W | 7 inch |
| Back left | 1,800 W | 7 inch |
| Back right | 3,600 and 1,400 W | 9 inch and 6 inch, dual ring |
| Front right | 1,200 W | 6 inch |
The back right zone is a single physical element carrying two switchable rings. So a customer reporting that the wide ring stays cold while the small one heats is describing one part, not two.
The same sheet has that cooktop hard wired on a 40 amp circuit with no plug. The reset lives at the panel, not at a socket.
Bosch sends a cracked glass top straight to a service technician. We treat it the same way, and we ask you to stop using the top until we have seen it.
One scope note before you book. We do not service induction cooktops on any brand, so if the glass beside the pan stays cool, we are the wrong call.
The hood above the cooktop is a different machine and a different call. Ventilation sits on our Bosch range hood repair page.
Work Bosch’s own free list first, in this order.
Then it becomes our job. Call when one burner still will not light while the others do. That points at the burner, the valve or the igniter rather than the supply.
Call when every burner is dead, when the flame will not hold, or when a radiant zone heats on one ring only. We have seen all three in Denver Metro kitchens.
Book online with the E-Nr from the rating plate to hand. Bosch looks its cooktop parts up by that number, and so do we.
Bosch sells its gas cooktop spares in named categories, and that list is a fair map of what fails. Burner caps and rings, ignition parts, thermocouples, grids, seals, holders and the cooktop itself.
On a visit it usually comes down to the igniter and the spark module, the gas valve and the thermocouple. Then the burner cap and burner head. On a radiant top it is the element or the touch control.
One honest note on naming. Infinite switch is a trade term rather than a Bosch one, and it appears nowhere in Bosch’s published material for these cooktops. Bosch’s failure vocabulary here is the code set instead.
We do work on parts like that. We show you the failed part rather than quote a Bosch name that does not exist.
Coverage across every brand sits on our cooktop repair and range and stove repair pages. The oven cavity and Bosch wall ovens are on Bosch oven repair, and the appliance as a whole on Bosch range repair.
The rest of the line starts from Bosch cooking appliances and Bosch appliance repair. Every repair carries a 100-day labor warranty, and we source Bosch parts through national supplier networks and manufacturer contracts.
Because Bosch built it that way. Its own caution reads that all igniters spark when any single burner is turned on, so every burner clicking is normal.
Look at the display first. F2, F4 or F5 with the ignition dead is overheated electronics, and it clears on cooling. Without a code, check the gas valve, the power supply and the igniters.
Bosch defines it as supply voltage outside the normal operating range. Its first instruction is to contact your electrical utility provider, because the fault is not in the appliance.
No. We do not service induction on any brand, cooktop or range. Send us the model number and we will tell you before anyone is dispatched.
Yes, and Bosch requires a qualified technician or installer for it. The work reaches inside the valves, and the kit Bosch ships for a cooktop will not convert a range.
It depends which part failed. A burner cap and a gas valve are not the same job. We diagnose first and quote second, and you decide before any part is ordered.
Nobody can tell you honestly, including us. Bosch puts no service life on a cooktop, so any number you find was invented by whoever published it. What decides the question is which part failed, and that comes out of the diagnosis.
Bosch cooktop repair near me and Bosch gas cooktop repair reach this same team, from Denver out through Aurora, Lakewood and Centennial.
Every igniter sparks when one burner is lit, and that alone is normal. Tell us what you see and we will say what is not.
Expert advice, maintenance tips, and troubleshooting guides for Bosch appliances from our technicians.

You pull open the freezer on a July evening and find an empty bin. A Frigidaire ice maker not working in peak summer is one of the most frequent calls our Denv…

You came here because your Samsung fridge is not making ice, and you also want to know whether you should be paying for this repair at all. Both questions have…

A Wolf oven not heating up is one of the more stressful appliance failures a homeowner can face. The unit is expensive, integrated into your kitchen, and not s…

A Sub-Zero freezer not working is a different situation from almost any other appliance failure. You are looking at a high-value built-in unit that is part of…

The drum is spinning. The timer is counting down. Clothes are coming out cold and damp. If you are asking why is my Samsung dryer not heating, you are in the r…

"My Frigidaire dishwasher won't start" this is one of the most common service calls we handle at Wilson & Myers, and it is not always a broken machine. A s…

Maytag washer stuck on sensing refuses to move past that first stage of the cycle, it's very common thing. Homeowners in Denver Metro are calling us daily with…

Whirlpool refrigerator is not cooling and you are not alone. This is one of the most common service calls we get at Wilson & Myers. The good news: most cau…

Your Bosch dishwasher is showing a E15 error and the drain pump is running non-stop. The pump is not broken. AquaStop is doing exactly what it was built to do…

A Sub-Zero refrigerator not cooling is a serious issue, and in most cases it is diagnosable and repairable. The trick is knowing how Sub-Zero units are built…

A Samsung fridge not cooling is rarely a random failure. Samsung refrigerators break down in specific patterns tied to specific models and years. At Wilson &am…

An LG refrigerator not cooling is one of the most common calls we get at Wilson & Myers. The answer depends on three things: is the freezer still cold? Is…
Wilson & Myers dispatches insured technicians to homes running Bosch appliances throughout the Denver Metro Area.
The data plate on a cooktop sits underneath, which changes how the visit starts. Send us the model and we will book a technician.

diagnostic from $69
Wilson & Myers is a verified member of the Denver Metro Chamber of Commerce.
The use of any materials from this resource is possible only after the written consent of the copyright owner.