Wilson & Myers repairs Pitco commercial fryers for restaurants and quick-service kitchens across the Denver Metro Area. Our insured technicians handle ignition, heating, and filtration faults.
Pitco has been building commercial fryers since 1918. J.C. Pitman started the company in Boston after noticing that food particles falling into the heat zone were causing burned results, and he designed the first Pitco Frialator to keep the cold zone and hot zone separated. That fundamental design has been in continuous production ever since. Today the brand is made in Concord, New Hampshire, as part of Middleby Corporation, the same group that owns Blodgett. Pitco holds the largest share of the global commercial fryer market. A fryer Pitco operators know by reputation as the most reliable frying platform in the industry.
We service the full Pitco lineup across Denver Metro. The Pitco frialator fryer in all configurations: gas, electric, ROV, countertop, filtration systems, and specialty fryers. For commercial fryer repair across other brands, see our commercial fryer repair page. Related equipment: commercial oven repair and Blodgett.
Workhorse of the Pitco lineup. The Pitco sg14 fryer and SG18 are the models that have been running in Denver restaurant kitchens for decades, and the fault pattern on high-cycle gas units is consistent: thermopile failure, pilot light problems, and gas valve issues account for the majority of service calls. These are not complicated repairs when the technician knows the architecture. The Pitco fryer sg14 and SG18 share the same basic heat system, so diagnostic time is short.
The Frialator in the 40D configuration is the twin-vat version. The 40d fryer runs two separate vats from one floor unit. Operators know it as the Pitco double fryer. The Pitco 40d fryer and Pitco fryer 40d are the same unit by two common names. That twin configuration shares a gas train, which means a single gas valve fault can take both vats offline simultaneously. We source Pitco fryer parts for all major gas floor configurations through national supplier networks and manufacturer contracts. Book online or call a pro to confirm availability.
Higher efficiency and more components. The Pitco solstice supreme fryer is the gas model built around Pitco’s Solstice technology for faster heat recovery and lower energy consumption. ROV stands for Reduced Oil Volume: cuts oil use by around 40% compared to a standard open-pot fryer while maintaining output. The ROV and Solstice models add the Infinity Touch Controller and built-in filtration to the basic gas fryer architecture. More components, more fault points.
The Pitco fryer filter system on Solstice models uses a filter drawer that cycles oil automatically. Filter drawer jams and pump failures are the most common service calls on these units. Not a major repair. We source Pitco frialator parts for Solstice and ROV configurations. Book online or call a pro to confirm scheduling.
No pilot, no thermopile, no gas valve. The Pitco electric fryer lineup covers floor models and countertop configurations with a completely different fault profile from gas units. The most common electric fault is element burnout, where one or more heating elements fail and the fryer either stops heating or takes too long to recover between loads. Element replacement is a straightforward repair on most Pitco electric models.
The Pitco commercial deep fryer in countertop configuration, the SGC series, is compact. Common in food trucks, catering setups, and smaller restaurant stations. Same fault profile as the floor electric models but in a smaller footprint. Specialty units including the Pitco donut fryer are also in our service scope. We source Pitco deep fryer parts for floor, countertop, and specialty electric units. Book online or call a pro to schedule a diagnostic.
The most common service call on gas Pitco units. Pitco fryer heat failure almost always traces to the thermopile on standing pilot models. The thermopile generates a small electrical current from the pilot flame heat, and that current holds the gas valve open. When it wears down, the current drops below the valve threshold and the fryer stops heating even though the pilot is still lit. Flame burning, no heat output. That is the Pitco fryer thermopile fault pattern, and misdiagnosing it as a gas pressure problem wastes time and parts.
At Denver’s elevation, gas pressure runs lower than sea level specification. Lower pressure, faster thermopile wear. It also affects flame stability on the pilot. We check and calibrate gas pressure on every Pitco gas fryer call in Denver Metro. For Pitco fryer troubleshooting that starts with a reset button trip: that is a thermal protection fault that needs a root cause diagnosis rather than repeated resets. Book online or call a pro for Pitco fryer repair near me across Denver Metro.
Older and newer Pitco models fail differently on ignition. On the SG14 and SG18, the Pitco fryer pilot light that won’t stay lit almost always means a dirty or misaligned thermocouple tip, a blocked pilot orifice, or a draft issue in the installation. Pilot light problems on these units are among the easiest service calls we handle. Twenty minutes in most cases.
On Solstice models with the Infinity Touch Controller, the ignition system is electronic. No standing pilot. Ignition faults show as a lockout code on the display rather than a physical pilot issue. The Pitco fryer not turning on fault on Infinity Touch units almost always traces to the ignition module or a flame sensor. We source Pitco fryer parts for both standing pilot and electronic ignition configurations. Book online or call a pro for Pitco fryer repair service across Denver Metro.
Separate from the heat system entirely. The Pitco fryer filter system on ROV and Solstice models is its own mechanical assembly. Filter pump failure is the most common fault: the pump stops cycling oil and the filtration drawer either won’t open or won’t drain. Running without filtration shortens oil life and affects food quality before any visible fault appears. Not a dramatic breakdown, but an expensive one if ignored.
The Pitco fryer drain valve is a separate point of failure on all floor models with a drain system. A stuck or leaking drain valve is a safety issue, not just a maintenance call. We source Pitco deep fryer parts and Pitco frialator parts for filter pumps, drain valves, and oil management components. Book online or call a pro for commercial fryer repair near me service.
Insured. A 100-day labor warranty on every Pitco fryer service call. Our technicians know the SG14, SG18, 40D, Solstice Supreme, and ROV platforms. For Pitco fryer repair service and commercial fryer repair service near me across Denver Metro, we cover gas and electric floor models, Solstice Supreme, and ROV platforms across the full service area. Book online or call a pro for availability.
We also repair Frymaster, Henny Penny, Imperial, and all other commercial fryer brands across Denver Metro. For commercial fryer repair near me across all brands, see our commercial fryer repair page. Full list on our appliance brands page.
Service area: Denver, Aurora, Lakewood, Littleton, Centennial, and surrounding communities.
Who repairs Pitco fryers in Denver?
Wilson & Myers services Pitco commercial fryers throughout Denver Metro. Gas and electric floor models, Solstice Supreme, ROV, Frialator, and countertop units. Book online or call a pro to check scheduling.
Why is my Pitco fryer not heating?
On gas models, the thermopile is the most common cause of Pitco fryer heat failure. It generates the current that holds the gas valve open, and when it wears down, the valve closes even though the pilot is still lit. It looks like a gas problem but it isn’t. On electric models, element burnout is most likely. Both involve a single component replacement. Book online for a diagnostic.
Are Pitco fryer parts available in Denver?
Yes. We source Pitco fryer parts and Pitco frialator parts for common fault components across the SG, 40D, and Solstice series. Parts are sourced through the Middleby network. Book online or call a pro.
My Pitco fryer keeps tripping the reset button. What does that mean?
The Pitco fryer reset button trips when the thermal protection activates from overheating. If it resets and the fryer runs normally, watch for a blocked thermostat bulb or a thermostat that’s not reading oil temperature correctly. If it trips repeatedly, there is a fault that needs diagnosis, not just another reset. Repeated reset trips can lead to element or heat exchanger damage if the root cause isn’t found. Book online to schedule a diagnostic.
Do you service Pitco filtration systems?
Yes. We service the Pitco fryer filter system on Solstice and ROV models, including filter drawer jams, pump failures, and drain valve faults. Filtration faults are a separate service from heat system faults. Book online or call a pro to confirm availability.
Does Denver's altitude affect Pitco gas fryers?
Yes. At 5,280 feet, gas pressure runs lower than sea level specification. This affects pilot flame stability, accelerates thermopile wear on high-cycle units, and can cause the fryer to run below rated temperature without triggering a fault code. We calibrate gas pressure on every Pitco gas fryer service call in Denver Metro to account for elevation.
Do you repair other commercial fryer brands?
Yes. We service Frymaster, Henny Penny, and all other commercial fryer brands. For full commercial coverage across Denver Metro, see our commercial fryer repair page. It covers restaurant fryer repair near me for all brands.
Denver kitchens lose covers when a fryer drops out. Tell us the Pitco model, whether it is gas or electric, and what the thermostat is doing. We diagnose on site and order the correct part once the fault is confirmed.
Repair guides, maintenance tips and troubleshooting walkthroughs written by our insured technicians.

Most cases of a Maytag dryer not heating split at the model prefix on the door: MGDC is gas, MEDC is electric, and the path diverges from there. On a Centennia…

You open the freezer Friday night and the GE side-by-side ice bin is empty, but the food is cold and the water dispenser works fine. Most GE refrigerator ice m…

A Samsung washer not spinning leaves clothes wet in the drum and the dryer waiting. Samsung's four platforms handle this differently: WF front-load, WA top-loa…

You opened the KitchenAid freezer this morning and the bin was empty. In my experience, the arm is the first thing worth checking: the fix costs nothing and ta…

A Frigidaire oven not heating can come down to a setting rather than a part. Before you book a repair, two checks cost nothing and take under a minute: the clo…

A Whirlpool dryer that tumbles but never heats traces to one of five faults, and three of them cost nothing to check. Here is the order to work through them, p…

F8 E4 means water reached the drip tray, not a fill fault. Here is the two-step reset and why it can fire on a brand-new install with a dry tray…

A Bosch dishwasher E22 error means one thing: the filter is blocked, and there is probably water sitting in the bottom of the tub…

A Frigidaire refrigerator not cooling is not always a broken refrigerator. The display on the door settles that question in about ten seconds…

You walked into the laundry room and the display is flashing D80. The drum is still turning. You do not know whether to stop the cycle or let it finish. D80 is…

A GE refrigerator not cooling usually falls into one of two failure paths. The question is simple: is the freezer still cold? If yes, the sealed system is inta…

You pull open the freezer on a July evening and find an empty bin. A Frigidaire ice maker not working in peak summer is one of the most frequent calls our Denv…
Wilson & Myers dispatches insured technicians to restaurants and quick-service kitchens running Pitco fryers throughout the Denver Metro Area.
From ignition and high-limit faults to filtration and temperature-control repair, Wilson & Myers services the full Pitco line across the Denver Metro Area.
Downtime in business? Get fast commercial appliance repair with authentic parts & advanced methods. Perfect for restaurants & offices!
Professional appliance installation by insured technicians following industry standards. Safe setup for ovens, dishwashers and more, so you avoid DIY errors!
Wilson & Myers is a verified member of the Denver Metro Chamber of Commerce.
The use of any materials from this resource is possible only after the written consent of the copyright owner.